EQ-TR-2026-014 MAY 2026 v0.3 — DRAFT

re:3D GigabotX 2 XLT 900 Power Assessment at JIFX 26-3

Continuous-waveform measurement of a re:3D GigabotX 2 XLT 900 large-format pellet printer during printing operations at JIFX 26-3 (Naval Postgraduate School). 24.8 h capture across two printing sessions delivered 4.08 kWh across 12 parts; peak draw ≈ 1.30 kW (peak RMS current ≈ 10.8 A on a 20 A circuit); supply within ANSI C84.1 Range A for >99 % of the window. Voltage and current channels bench-calibrated against a Siglent SDM3065X-SC reference.

Field Assessment FGF Printer CPOW JIFX 26-3